FANUC Roboshot (Injection Molding)
FOCAS is rarely available on Roboshot machines. Test for it before planning a FOCAS connection — the alternatives are covered at the end of this page.
Control Type: FANUC-based (injection molding machines)
FOCAS Support: Rarely available on Roboshot machines
Special Considerations:
- Roboshot machines (injection molding) rarely have FOCAS capability
- Even if the machine has a FANUC control, FOCAS may not be enabled
- Unlike CNC machines, injection molding controls often use different communication protocols
- In our experience, it is unlikely to support FOCAS
Testing for FOCAS Support on Roboshot
Before attempting full FOCAS configuration, test if FOCAS is available:
Step 1: Configure IP Address
- Access network settings on the Roboshot control
- Assign a static IP address to the machine
- Note the IP address for testing
Step 2: Test FOCAS Port (Telnet Test)
-
From a computer on the same network, open terminal/command prompt
-
Run telnet command to test FOCAS port:
telnet [MACHINE-IP] 8193Replace
[MACHINE-IP]with the machine's IP address -
If FOCAS is available:
- Connection will succeed
- You may see a blank screen or connection message
- This indicates FOCAS port 8193 is open
-
If FOCAS is NOT available:
- Connection will fail or timeout
- Error: "Unable to connect" or "Connection refused"
- This indicates FOCAS is not supported
Step 3: Determine Next Steps
If Telnet Test Succeeds:
- Proceed with standard FOCAS configuration
- Follow standard FANUC setup steps
- Add machine in MachineMetrics using FOCAS adapter
If Telnet Test Fails:
- FOCAS is not supported on this machine
- Alternative: Use Digital I/O connectivity instead
- Contact MachineMetrics support for recommended approach
- May need sensors and I/O hardware for data collection
Alternative Connectivity for Roboshot
If FOCAS is not available (most common case):
Recommended: Digital I/O Connectivity
- Install current transducer on hydraulic pump motor
- Capture part eject signal or cycle complete signal
- Use Sealevel or WISE I/O module
- Configure via Modbus TCP
Contact Support:
- Reach out to MachineMetrics support with your Roboshot model
- We can recommend the best connectivity approach
- May have experience with your specific model