Skip to main content

Kitamura Troubleshooting

SymptomLikely causeAction
AnyWhere Remote icon missing (Mi)App not installed on the controlContact Kitamura for the USB installer
MTConnect shows NOT ENABLED (Mi)License not installedComplete the license request and install steps above
Ping fails to the CNC IP (Jr)Network or parameter issueCheck parameters 1925–1928, cabling, and subnet match
Telnet Connect failed on 7878 (Jr)Adapter service not running, or wrong portStart the service and confirm the port in the config file
Telnet connects but shows nothing (Jr)Adapter can't reach the CNCVerify host IP and model in Adapter Configuration.ini
ERR_CONNECTION_REFUSED on the agent URL (Jr)Agent not running, or wrong portCheck the agent service and port number
Availability = UNAVAILABLE (Jr)Adapter not running, or can't reach the CNCWork back through Tests 1 and 2
Machine drops offline and comes back (Jr)Adapter losing its CNC connection intermittentlyWork through Intermittent drops
Adapter log shows network error 0x8202000A (Jr)Adapter stuck instead of reconnectingSet Close After Disconnect = enabled in the config file, then stop, re-install settings, and start the service
Works locally, not from the network (Jr)Windows FirewallAllow inbound traffic on the agent port
Adapter service won't start (Jr)Port or service-name conflictEnsure unique ports, service names, and directories per machine
Config changes not taking effect (Jr)Settings not re-installedStop the service, run install_<SN>_service.bat, then start the service
Silent-install failures (Jr)See the installer logCheck IMA Standard Adapter – Installer.log next to the installer executable

For MTConnect problems that are not specific to Kitamura, see Troubleshooting in the MTConnect guide and Machine Not Reporting.


IMA Adapter Diagnostics​

These apply to an Arumatik-Jr running the Mitsubishi IMA Standard Adapter. See Arumatik-Jr for the install itself.

Logging​

Adapter logs are written to the install directory as sAdapter_<log number>.log, in the format Timestamp | Severity | Message. Severity levels from lowest to highest are trace, debug, info, warning, and fatal. Log rotation defaults to 2 MB per file and 10 MB total, deleting the oldest file first. These logs are the first place to look when troubleshooting remotely.

Intermittent drops: the machine keeps going offline​

When machines drop offline and come back, and the MTConnect agent shows Availability = UNAVAILABLE during the drops, it almost always means the IMA adapter is losing its connection to the CNC intermittently. Work through the checks below in order — they are listed by likelihood.

1. Confirm where the adapter is running.

It needs to be on a dedicated PC or server that is on 24/7 and on wired Ethernet — not a laptop, and not a desktop that sleeps. On that machine:

  • Set the Windows power plan to never sleep.
  • In Device Manager, open the network adapter's Power Management tab and uncheck Allow the computer to turn off this device to save power.

2. Pull the adapter logs.

In the adapter install directory you will find sAdapter_1.log, sAdapter_2.log, and so on. Note the timestamps when machines drop and read what was logged at that moment.

If the logging severity in the config file is set to warning or fatal, change it to info so connection events are captured, then stop the service → run install_<SN>_service.bat as Administrator → start the service. Config changes do not take effect until the settings are re-installed.

3. Enable Close After Disconnect in the config file.

Open configure_<SN>.bat and, in the [Adapter] section, set:

Close After Disconnect = enabled

This is disabled by default, and when the adapter hits network error 0x8202000A it can get stuck instead of reconnecting. If your logs show that error code, this is very likely the fix. Apply it with the same stop → install → start sequence.

4. Run a long ping test during production.

From the adapter PC, run a sustained ping and let it go for a full shift:

ping -t <CNC IP address> > ping_log.txt

Intermittent timeouts in the log point to a physical or network problem rather than the adapter: a flaky cable to the machine, a failing switch port, or an IP conflict on the machine network.

5. Check whether the adapter service itself is crashing.

The service restarts automatically by default, which can hide crashes. In Windows Event Viewer, open the System log and filter for Service Control Manager events around the drop times.