Kitamura Arumatik-Jr
The Arumatik-Jr — the smaller 15" screen — has no AnyWhere Remote and therefore no built-in MTConnect adapter. The usual answer is the Mitsubishi IMA Standard Adapter running on a Windows PC, which reads the CNC and publishes MTConnect for the Edge device.
Edge connects to: the Windows PC running IMA, not the machine · Address: PC IP
plus the agent port set during install (default 5000) ·
Verify with: http://<pc-ip>:<agent-port>/current
The Arumatik-Jr control does not include AnyWhere Remote, so there is no built-in MTConnect adapter. There are two paths:
- Mitsubishi IMA Standard Adapter — a Windows application that reads the CNC and publishes MTConnect. Recommended.
- Upgrade the controller — contact Kitamura about moving to a newer control that supports AnyWhere Remote.
Option 1: Mitsubishi IMA Standard Adapter
The Arumatik-Jr is built on a Mitsubishi Electric NC, so it can be connected with the Mitsubishi Integrated Machine Analytics (IMA) Standard Adapter V3.3 — a Windows application that reads data from the CNC and publishes it to a listening MTConnect Agent. The IMA installer packages both the adapter and an MTConnect Agent in a single executable. IMA V3.3 is compliant with version 2.2 of the MTConnect Standard.
The installer, license keys, and the IMA Installation, Configuration, and User Guides all come from Mitsubishi Electric Automation: software.solutions@meau.com or 847-478-2100.
The IMA adapter produces an MTConnect stream that MachineMetrics reads over HTTP. You are not using the MachineMetrics Mitsubishi adapter — in MachineMetrics you add the machine as an MTConnect machine pointing at the IMA agent.
Compatibility: read this first
The IMA adapter supports CNC machines with standard Mitsubishi Electric NCs:
- M800 / M80 series
- M700 / M70 series
Confirm the NC series on the Arumatik-Jr with Kitamura before ordering a license.
Support is not available for Mitsubishi Electric controls on machines from these tool builders:
| Tool builder | Supported by IMA adapter? |
|---|---|
| Mazak | ❌ No |
| Citizen | ❌ No (except M800 / M80 series and newer) |
| Traub | ❌ No |
| DMG MORI | ❌ No (except M730 and newer) |
These builders use customized Mitsubishi controls that the standard IMA adapter cannot read. If a shop wants to connect one of these machines with this adapter, stop — it will not work.
Host PC requirements
The adapter must run continuously to stream machine data. Install it on a dedicated PC or server in a server room with 24/7 access to the machine network. If the host sleeps, shuts down, or leaves the network, data collection stops.
- Windows 8 or newer
- Static IPv4 address on the same network as the CNC — the first three octets must match the CNC (for example,
192.168.200.###) - Powered on and network-connected 24/7
Licensing
The adapter is a CNC-specific application: each installation is licensed against one CNC's NC serial number. The installer validates the license key against the serial number you enter, and the Install button only becomes enabled once verification passes.
The serial number is used throughout the install — it becomes part of the batch file names, the Windows service identity, and the MTConnect device and data item names. Record it accurately.
Data packages: purchase Package #4
The IMA license is sold as a base package plus optional add-on packages. Only the data items in the packages you purchase are published by the adapter. Decide which packages you need before ordering, because adding one later requires a new license key from Mitsubishi Electric Automation.
Program Comment and Program Comment: Active are in Package #4 (Program #1 Option), not the base package. Without Package #4, the IMA adapter does not publish program comment data, so MachineMetrics cannot run Automatic Production Monitoring (APM) on the machine.
Purchase Package #4 alongside the base package when you order the IMA license.
What MachineMetrics recommends at minimum: Base Package plus Package #4. Packages #6 (Spindle), #7 (Load), and #3 (Assets) are worth adding if you want spindle speed and load, or tool number reporting.
Available packages:
| Package | Data items |
|---|---|
| Base Package | Availability, Controller Mode, Emergency Stop, Execution State, Override (Programmed Path Feedrate, Rapid Path Feedrate, Rotary Velocity), Message, Part Count (All, Remaining, Target), Process Timer, Program (Active, Main), Serial Number, Wait State, Alarms/Conditions |
| #1 Positioning | Angle (Actual, Commanded), Direction (Linear, Rotary), Path Feedrate (Actual, Programmed), Path Position Commanded, Position (Actual, Programmed) |
| #2 Overrides | Dry Run, Machine Axis Lock, Single Block |
| #3 Assets | Tool Asset ID, Tool Number, Tool Number Standby |
| #4 Program #1 (required for APM) | Block, Line Label, Line Number Absolute, Program Comment, Program Comment Active, Program Header, Program Header Active |
| #5 Program #2 | Program Edit, Program Edit Name |
| #6 Spindle | Direction Rotary, Rotary Mode, Rotary Velocity (Actual, Commanded, Programmed) |
| #7 Load | Load |
| #8 Status | Active Axes, Equipment Mode (Feeding, Rapid, Tapping, Threading) |
| #9 Timers | Accumulated Time (Automatic, Cycle Start, MTB Ext. Time #1, MTB Ext. Time #2), Equipment Timer (Loaded, Powered), Clock Time |
Notes on package availability:
- Packages are available with IMA version 3.3.9 and newer.
- MTB (machine tool builder) alarms are not supported by the base package Alarms/Conditions item.
- The Edit value for Controller Mode, and Program Edit Name in Package #5, are only supported on standard M8 series NCs.
Confirm the package list and pricing with Mitsubishi Electric Automation: software.solutions@meau.com or 847-478-2100.
CNC parameters
Before connecting, verify the following parameters on the control (refer to the machine manual for parameter access):
| Parameter # | Name | Purpose |
|---|---|---|
| 1925 | Ethernet | Enables the Ethernet connection |
| 1926 | Global IP Address | IP address of the CNC on the network |
| 1927 | Global Subnet Mask | IP network grouping |
| 1928 | Global Gateway | IP address of the router or forwarding host |
Write down parameter #1926 — you enter it during the install and use it to test connectivity.
Installation walkthrough
Run IMA Standard Adapter Setup on the host PC, with all other applications closed.
Step 1: Choose the installation location.
The default is C:\Program Files (x86)\IMA_Standard_Adapter.
When installing multiple adapters or agents on the same PC, each installation must go in its own directory. Include the machine ID and the NC serial number in the path, for example C:\Program Files (x86)\IMA_MYCENTER-1_<SN>\.
If a Standard_Adapter.exe already exists in the selected directory, the installer warns you that a copy of the software is already installed. Clicking OK updates the existing install in place. If you are adding a second machine, do not click OK — that overwrites the first machine's adapter. Click Cancel and choose a new directory. Only click OK when you are intentionally updating an existing installation.
Step 2: Choose components.
| Install option | What it installs |
|---|---|
| Everything | Adapter + runtime library + MTConnect Agent |
| Adapter (only) | Adapter + runtime library |
| Agent (only) | MTConnect Agent only |
| Custom | User-selected components |
For a standard single-PC install, choose Everything. Accept both license agreements when prompted.
Step 3: Set the adapter service name and port.
The installer prompts for an Adapter Service Name (default IMA Standard Adapter) and an Adapter Port (default 7878).
Windows will not run two services with the same name, and two programs cannot bind the same port. If the installer warns about a duplicate name or an occupied port, do not click through it — go back and change the value.
Put both a machine ID and the NC serial number in every service name. The serial number keeps the name unique and ties the service to its license, but most people don't know a machine by its serial number. Adding the machine ID — the same name the machine has in MachineMetrics, or the asset tag on the machine itself — is what lets someone find and restart the right service months from now.
Recommended convention when hosting multiple machines on one PC:
| Machine | Adapter service name | Adapter port | Agent service name | Agent port |
|---|---|---|---|---|
MYCENTER-1 | IMA Standard Adapter MYCENTER-1 <SN1> | 7878 | MTConnect Agent MYCENTER-1 <SN1> | 5000 |
MYCENTER-2 | IMA Standard Adapter MYCENTER-2 <SN2> | 7879 | MTConnect Agent MYCENTER-2 <SN2> | 5001 |
HX400 | IMA Standard Adapter HX400 <SN3> | 7880 | MTConnect Agent HX400 <SN3> | 5002 |
Step 4: Set the agent service name and port.
The same uniqueness rules and naming convention apply. The default agent name is MTConnect Agent and the default port is 5000. The agent port is the port MachineMetrics (or a browser) queries.
Step 5: Enter the CNC settings.
Enter the CNC's IP address (parameter #1926) and select the NC type and series from the CNC Configuration drop-down that matches the machine's Mitsubishi control.
Step 6: Enter licensing details.
Enter the NC Serial Number and the License Key. Once verified, click Install, then Finish.
Post-install: know your batch files
The install directory contains batch files keyed to the NC serial number. Run them as Administrator (right-click → Run as Administrator):
| File | What it does |
|---|---|
configure_<SN>.bat | Opens the configuration file (Adapter Configuration.ini) in Notepad |
install_<SN>_service.bat | Applies the configuration file settings to the Windows service |
start_<SN>_service.bat | Starts the adapter Windows service |
stop_<SN>_service.bat | Stops the adapter Windows service |
restart_<SN>_service.bat | Stops the service, applies config settings, and starts it again |
debug_<SN>.bat | Runs the adapter in a console window with debug-level logging |
Always stop the service → run install_<SN>_service.bat → start the service. Config changes are not picked up until the settings are re-installed.
The Windows services install with Automatic startup and Service Restart enabled by default, so the adapter survives PC reboots — one more reason this belongs on a server rather than a laptop.
Testing: verify every layer before leaving site
Test in this order. Each step proves one layer, so when something fails you know exactly where.
Test 1: The PC can reach the CNC (network layer).
On the host PC, open Command Prompt:
ping <CNC IP address from parameter #1926>
- Pass: replies with
bytes=,time=, andTTL=, at 0% loss. - Fail:
Destination host unreachable,Request timed out(100% loss), orGeneral failure. Fix the network before continuing — check parameter #1925 (Ethernet enabled), the cable, and that the PC and CNC are on the same subnet.
A short ping proves the network works right now. If the machine connects but drops offline intermittently, run a sustained ping instead — see Intermittent drops.
Test 2: The adapter is running and gathering data (adapter layer).
Option A — run the adapter in debug mode and watch the console:
debug_<SN>.bat
You should see pipe-delimited data streaming in the format Timestamp | Data Item Name | Data Item Value. An empty console means the adapter is bound to the port but not connected to the CNC — recheck the host IP and model in the config file. Close the console and start the Windows service when you are done.
Option B — telnet the adapter port (Telnet must be enabled in Windows Features):
telnet 127.0.0.1 7878
- Pass: pipe-delimited data appears.
Connect failed: nothing is bound to the port — the adapter service isn't running, or it's on a different port.- Connected but empty: the adapter is running but is not talking to the CNC.
Test 3: The agent is serving MTConnect data (agent layer).
On the host PC, open a browser to http://localhost:<agent port>/current (for example, http://localhost:5000/current).
ERR_CONNECTION_REFUSED: the agent isn't running, or it's on a different port.- Find the Availability data item in the XML:
AVAILABLE— the adapter is running and connected to the CNC.UNAVAILABLE— the adapter is not running, or is running but can't reach the CNC. Go back to Tests 1 and 2.
Test 4: The agent is reachable from the network (MachineMetrics layer).
From another machine on the network, such as the Edge device, browse to http://<host-pc-ip>:<agent port>/current.
- Pass: the same XML as Test 3.
- Fail while Test 3 passes: Windows Firewall is blocking the agent port. Add an inbound rule allowing the agent port.
Test 5: It survives a reboot.
Reboot the host PC, wait for it to come back up without logging in, and repeat Test 4. The adapter and agent services should start automatically. If they don't, check that the service startup type is set to Automatic.
Only after all five tests pass, add the machine in MachineMetrics as an MTConnect connection pointing at http://<host-pc-ip>:<agent port>. See Adding the Machine in MachineMetrics.
Option 2: Upgrade the Controller
Contact Kitamura about upgrading the Arumatik-Jr to a newer control that supports AnyWhere Remote. Once the machine is upgraded, follow the Arumatik-Mi instructions above — no separate host PC or adapter software is needed.