Mitsubishi Troubleshooting

Cannot Connect to Machine​

Problem: Connection test fails when adding machine.

Solutions:

  1. Verify IP Address

    • Confirm IP address on machine control
    • Check for typos in MachineMetrics
  2. Verify Port Number

    • Port 683 is used for all Mitsubishi connections
    • Check control network settings if connection fails
  3. Check Network Connectivity

    • Ping machine from Edge device or computer
    • Ensure machine and Edge are on same network/VLAN
    • Check firewall rules
  4. Verify Machine Powered On

    • Control must be powered on
    • Ethernet communication must be enabled

No Data Appearing​

Problem: Machine connects but no data displays in MachineMetrics.

Solutions:

  1. Check Adapter Settings

    • Verify correct adapter type selected
    • Review Data Collection tab
  2. Run a Program

    • Some data only appears during operation
    • Load and run a test program
  3. Check Control Settings

    • Ensure external communication enabled
    • Verify no security restrictions blocking data

Part Count Not Incrementing​

Problem: Part count stays at zero or doesn't increment.

Solutions:

  1. Verify Part Count Method

    • Go to Machine Settings → Data Rules
    • Use Select Part Count Metric to choose the correct counter source
  2. Check M-Code Configuration

    • Check if M-code is in program (if using M-code method)
    • Ensure signal is configured (if using signal method)
  3. Run Complete Cycle

    • Part count may only increment on M30 or program end
    • Run a full cycle to test

Wrong Adapter Type Selected​

Problem: Accidentally selected wrong adapter type.

Solution:

  1. Go to Machine Settings for that machine
  2. Click Data Collection tab
  3. Click Change Adapter or remove and re-add
  4. Select correct adapter (Mitsubishi M70 or Mitsubishi M700)
  5. Re-configure connection settings
  6. Test connection and save