IFM Master Block Setup
The Edge device talks to the master block, never to a sensor directly. The block needs a static IP on the same subnet as the Edge device, set through IFM's configuration software.
Connect to: the block's IoT port, which is separate from the fieldbus port · Protocol: IO-Link over Ethernet · MachineMetrics needs: the block's IP address only
Physical Installation and Ports
Step 1: Physical Installation
- Mount the IFM master block on DIN rail or suitable location
- Connect power supply to master block (24V DC typical)
- Verify power LED illuminates
Step 2: Identify IoT Port
IFM master blocks support multiple protocols on different physical ports:
- IoT Port - Required for MachineMetrics integration (Ethernet with RJ45)
- EtherNet/IP Port - NOT compatible with this integration
- Modbus Port - NOT recommended (requires manual configuration) - See Modbus TCP Guide if needed
Critical: Ensure you connect the IoT port (not EtherNet/IP or Modbus port) to your network.
Step 3: Connect to Network
- Connect network cable from the IoT port to your network switch
- Verify link lights on Ethernet port are active
Network Configuration
Step 1: Install IFM Configuration Software
- Download IFM's configuration software from: https://www.ifm.com/us/en/category/095_010_010
- Install on a PC connected to the same network
- Launch the configuration tool
Step 2: Discover Master Block
- Open IFM configuration software
- Click Scan or Discover Devices
- Locate your master block in the list (note MAC address if multiple devices)
Step 3: Assign Static IP Address
- Select your master block in the configuration software
- Navigate to Network Settings or IoT Port Configuration
- Set IP Configuration to Static (Manual)
- Enter network information:
- IP Address: (e.g., 192.168.1.150)
- Subnet Mask: (e.g., 255.255.255.0)
- Gateway: (e.g., 192.168.1.1)
- Click Apply or Write Configuration
- Document the IP address for MachineMetrics configuration
Step 4: Verify Configuration
- Disconnect configuration PC
- Reconnect to network
- Verify master block is accessible at the assigned IP address
- Test with ping:
ping 192.168.1.150
Sensor Port Configuration
Step 1: Set Port Operating Modes
IFM master blocks allow individual port configuration:
- In IFM configuration software, navigate to Port Configuration
- For each port you'll use, set mode to IO-Link
- Other modes (Digital Input, Digital Output) will not work with this integration
Step 2: Connect Sensors
- Connect IO-Link sensors to master block ports using M12 cables
- Ports are numbered (typically Port 1 - Port 8 or Port 1 - Port 4)
- Document which sensor is connected to which port
Step 3: Verify Sensor Detection
- In IFM configuration software, view Port Status
- Verify each connected sensor shows:
- Status: Connected or Active
- Vendor ID: Numeric identifier for manufacturer
- Device ID: Numeric identifier for sensor model
- Note the Vendor ID and Device ID for each sensor (useful for troubleshooting)
Related Articles
- Connecting Sensors — wiring sensors into the configured ports
- Data Collection — adding the block in MachineMetrics
- Troubleshooting — master block faults